FACADESXi MASONRY VENEER

Masonry Veneer Mortar Assembly

Masonry Veneer Mortar Assembly

This system is a tested and engineered wall assembly of thin veneers adhered to enhanced mortar beds with the most advanced, high strength mortar to ensure stone adhesion. FXI Masonry Veneer Systems offer the look of full sized stone, brick, with the lower weight for lower construction costs and schedules.

USES

Exterior, interior, high impact requirement, new, retrofit, residential, multi-family, commercial, panelized, institutional, hotels, hospitals, retail centers, schools, condominiums, and government facilities

DOWNLOAD DOCUMENTS

Code Reports:

Substrate
    With code compliant lath & water resistive barrier
  • ASTM C1177 glass mat faced sheathing
  • ASTM C79/C1396 exterior gypsum sheathing
  • ASTM C1325 Type A Exterior cement-board
  • Exposure I or exterior plywood sheathing (grade C-D or better)
  • Exposure I OSB
  • Poured concrete/unit masonry/brick
Direct Application (not shown)
  • Concrete, Concrete masonry (CMU), Poured concrete, brick
Code Compliant Water Resistive Barrier
  • Per Applicable International Building/Residential Code
  • -Wood Base Substrates: Minimum 2 layers (2018 IBC: Airspace/Drainage Mat may be required)
  • -Others per Applicable IBC/IRC
  • Code complaint sheet good with a current code Evaluation Report
  • Code compliant Air/Water Barrier Coating with a current code Evaluation Report
Code compliant lath
  • Metal Lath
  • Plastic Lath
  • Woven Wire
Mortar Bed/Stucco Base Coat / Xi-Admix & Bonding Agent
  • FacadesOne or FacadesThree Concentrate/Sanded: factory mix of portland cement complying with ASTM C150, chopped fibers, and proprietary ingredients mixed with water and sand (for concentrate) in the field. Must be mixed with Xi-Admix & Bonding Agent
Adhered Veneer Mortar
  • Xi-Masonry Veneer Mortar
Veneer Units
  • Manufactured Stone Veneer
  • Natural Stone Veneer
  • Thin Brick
  • Tiles
  • -Adhered Veneers are not to exceed 36 inches in any face dimension, 5 square feet in total face areas, 2-5⁄8 inches thick or 15 pounds per square foot.
  • Framed walls must terminate stucco a minimum of 4-inches above grade, 2-inches above finished grade, or as specified by local code.
  • Moist curing must be provided per specifications.
  • Ambient and surface temperature must remain above 40ºF (4ºC) during and for 24-hours after set has occurred.
  • Protect applied product from inclement weather until dry.
  • Efflorescence is a natural occurrence when using cement based products subject to exterior or wet environments.
  • No additives are permitted to any components unless specifically approved by FXI.
  • Follow the application instructions for each component.
  • Cracking will occur in portland cement stucco. This statement is true of any Portland cement based product and is not a defect of the product. Cracking can be minimized by following best practices in the FaçadesOne Stucco Handbook; including proper installation of lath, proper use of control and expansion joints, proper sand selection, proper proportioning of stucco mix, avoiding the use of excess water, moist curing of the stucco after it has been applied, and proper sequencing of construction to avoid stresses in the freshly placed stucco.
  • For use on vertical construction and on above grade walls only when installed on framed construction.
  • Maintenance Required: Follow Adhered Veneer Manufacturers' Recommendations.
  • Factory prepared mixed stucco base for consistent field quality control.
  • Impact and puncture resistant.
  • Warrantable Assembly
  • Reduced Labor
  • Shorter construction schedule
  • Lower Cladding Weight for decreased structural requirements
  • High Strength Mortar for Secure attachment